FaultData

Introduction
A record that represents a fault code record from the engine system of the specific Device.
Properties

amberWarningLamp

Whether the amber warning lamp is on. Only reported for J1939 faults; false for other fault types.

classCode

The DtcClass code of the fault.

controller

The Controller code related to the fault code; if applicable.

count

The number of times the fault occurred. For J1939 and J1708 faults, this is the occurrence count reported by the ECU. For other fault types it is 1, and each occurrence is a separate record.

dateTime

The date and time at which the event occurred.

device

The Device that generated the fault.

diagnostic

The Diagnostic associated with the fault.

dismissDateTime

The date and time that the DismissUser dismissed the fault.

dismissUser

The User that dismissed the fault.

effectOnComponent

The effect on component for enriched fault. Omitted when no enrichment is available for the fault's diagnostic.

failureMode

The FailureMode of the fault; if applicable. Populated for J1939 and J1708 faults (the failure mode identifier) and WWH-OBD/UDS faults (the failure type). Other fault types return NoFailureModeId.

faultDescription

The fault description for enriched fault. Omitted when no enrichment is available for the fault's diagnostic.

faultLampState

The FaultLampState of a J1939 vehicle. See FaultLampState for the possible values.

faultState

The FaultState code from the engine system of the specific device. Derived from the effective status in FaultData.faultStates, and only returns None, Pending or Active. Use FaultData.faultStates to read Inactive and Cleared statuses.

faultStates

The fault status from the engine system of the specific device. Returned as an object whose effectiveStatus property holds the FaultStatus that currently applies to the fault.

flashCode

The FlashCode associated with the fault.

id

The unique identifier for the entity. See Id.

malfunctionLamp

The malfunction light state. Only reported for J1939 faults; false for other fault types.

protectWarningLamp

Whether the protect warning lamp is on. Only reported for J1939 faults; false for other fault types.

recommendation

The recommendation for enriched fault. Omitted when no enrichment is available for the fault's diagnostic.

redStopLamp

Whether the red stop lamp is on. Only reported for J1939 faults; false for other fault types.

riskOfBreakdown

The risk of breakdown associated with the fault: the percentage chance, from 0 to 100, that the fault leads to a breakdown within the next 1,000 km. Omitted, or a negative value, when no valid estimate is available.

severity

The overall severity level of the fault. This value is determined by coalescing the following properties in order of precedence:
1. FaultData.overrideSeverity
2. FaultData.faultRichSeverity
3. FaultData.faultSeverity
4. FaultData.faultCycleSeverity
5. FaultData.diagnosticSeverity Effectively, this property represents the first available severity in this order. See DtcSeverity for the possible values and how each is labelled in MyGeotab.

sourceAddress

The source address for enhanced faults (for example WWH-OBD), identifying the module that reported the fault. Not populated for standard OBD-II or J1939 faults; for J1939 faults the reporting ECU is identified by FaultData.controller.
Rate limits
MethodDescriptionLimitPeriod
GetLimit of 500 Get requests per 1m.5001m
SetLimit of 1200 Set requests per 1m.12001m
AddLimit of 100 Add requests per 1m.1001m
RemoveLimit of 100 Remove requests per 1m.1001m
GetCountOfLimit of 100 GetCountOf requests per 1m.1001m
GetFeedLimit of 60 GetFeed requests per 1m.601m
Pagination

Results limit

50000

Supported sort

Id

Date sorts by the FaultData.DateTime property.

Timeout Limit
MethodDescriptionLimitStatus
GetFeed180Active